Change Log¶
Release 24.10¶
Release date: 31-Oct-2024
- PID indicator data (value, shift and error) are enabled and displayed in the PID/PLL tab of LabOne UI.
- PID indicator data (value, shift and error) can be streamed to the host computer. This can be controlled in the PID/PLL tab of LabOne UI.
- PID indicator data (value, shift and error) are available on Aux Outputs and can be selected in Aux tab of LabOne UI.
- Enabled the PID Advisor tool to simulate the behavior of a number of different DUT types in a feedback loop and choose feedback gain parameters based on the simulation.
- Enabled subscription to PID signals (value, shift and error) in the LabOne Sweeper module and Sweeper tab of LabOne UI.
- Consistent spectral measurement across Sweeper, Scope, Data Acquisition, and Spectrum tools.
Release 24.07¶
Release date: 31-Jul-2024
- Connected the Auxiliary Input channels to the Scope module to capture the digitized signals.
- Connected the Auxiliary Input channels to the Demodulators and enabled them for external reference.
- Added input range control for Auxiliary Inputs.
- Added input range utilization reporting for Signal Inputs and Auxiliary Inputs.
- Added user-configurable delay compensation for demodulated signals from Signals Inputs and Auxiliary Inputs.
- Oscilloscope: The Scope module of LabOne offers now Uniform averaging in addition to already available Exponential averaging.
Release 24.04¶
Release date: 30-Apr-2024
- GHF-MOD Modulation Analysis option that introduces two modulation units for sideband analysis is enabled.
Release 24.01¶
Release date: 31-Jan-2024
- DAQ module can acquire and analyze hardware-triggered demodulator data.
- Demodulator metadata provides information on frequencies and sources.
- Demodulator frequencies are included in the LabOne UI analysis tools.
- Bypassing the demodulator LPF is available in the LabOne UI.
- Demodulator input selectors are independent from the multi-frequency (MF) option.
Release 23.10¶
Release date: 31-Oct-2023
- GHF-PID Quad PID/PLL Controller Option is enabled.
- External reference (ExtRef) feature allowing the user to lock an oscillator to an external signal's frequency.
- Amplitude (R) and Phase (Theta) of the demodulated signals are now available at the Auxiliary Outputs.
- Demodulator data acquisition can be triggered via Trigger Inputs.
- Connectivity: Ethernet-over-USB on the USB 2 interface.
- Sweeper: Setting the start and stop points of the sweep parameter from the x-axis cursors in the Sweeper tab.
Release 23.06¶
Release date: 30-Jun-2023
- Initial release of the GHFLI User Manual.